However, because the status byte register is a summary of other registers, you can use enable registers to monitor other desired instrument events. For example, a command error is an error that occurs while the instrument is parsing a command or query. With command synchronization, you respond to the operation complete event. The Service Request Enable Register can be both set and queried. Each core register is described in more detail below.

Uploader: Fenrikus
Date Added: 7 February 2006
File Size: 20.57 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 30482
Price: Free* [*Free Regsitration Required]

With instrument error handling, you respond to error events in the Standard Event Status Register. Message 6 of Increase lbview input frequency up to 39KHz. The examples that include “learn” in the name are designed for interactive instruction.

Keysight Instrument Drivers | Keysight (formerly Agilent’s Electronic Measurement)

I still cannot figure out why it is not working. There are several advantages to using the dll form of the driver. If combined with a polling operation, can be used for other situations. Figure 3 shows a block diagram of a simple read and 33210a operation that incorporates the VISA Timeout property node to wait for data to be available.

Instrument Error Handling Some cases of Watching and Responding to Events If combined with a polling operation, can be used for other situations. Lower the frequency of the waveform generator to 6, 10, 14 Hz lagview show filter input vs output.

  AWLH 3025 VISTA DRIVER

Serial is famous for having an almostt correct cable. It includes a comprehensive on-line agilejt file which complements the instrument manual. Message 4 of However, for maximum portability, the instrument address should use uppercase characters only.

Keysight Technologies / Agilent Technologies hp33120a Signal Generator

Typically, query synchronization is used when the response from the instrument is not immediate. To answer, Recall the Sampling Theorem and be able to say something about your sample agilebt Therefore, the message available bit is set to true after the first measurement data is completed.

Serial poll is a special bus operation where the instrument controller obtains the status byte register value. Therefore, if the event changes, the associated bit in the condition register also changes.

using agilent a with labview – Discussion Forums – National Instruments

Query synchronization involves first sending a query command to your instrument. I read the stuff about drivers and i installed the specific agxxx driver for the func. Why do they call one of the waveforms Cardiac? I’m not interested in read-back at this point, only writing to the machine. The query status approach is nothing more than sending query commands to the instrument to read the instrument status registers. I notice that when I configure the IVI session name in the Configuration window, the resource descriptor and instrument driver fields are blank when I choose my hpa driver.

  FSV-510 PLUS WINDOWS 7 DRIVER DOWNLOAD

The standard event status register records eight different events that might occur on your instrument. Be aware that the amplitude of the spectrum peak may be much less than 1. See Chpt 1 of the Guide.

In this lab you will observe aliased frequencies. Message 1 of Message 2 of The standard event status register and the status byte register each have an associated enable register. If an event occurs, the event is removed from the VISA queue.

Agilent Technologies / Keysight Technologies 33120A

Although thousands of instruments perform a variety of different labvisw and stimulus operations, there is commonality in the types of instrument control operations you perform.

However, because the status byte register is a summary of other registers, you can use enable registers to monitor other desired instrument events.

This register defines such events as Voltage Overload and Ohms Overload. However, I found a strange thing I run this vi several times Will not appear on the error message, and do not know why?